Thursday, 19 November 2026

ISO 15848-1 Explained: What Fugitive Emission Classes Mean for Bellow Seal Valves

 A datasheet that says “ISO 15848-1 compliant” sounds reassuring. On its own, it says very little. The standard defines a family of classes, and a valve that reaches the loosest class and one that reaches the tightest both qualify to use the name. If you buy bellow seal valves for toxic or volatile service, you need to know which classes were actually achieved.

What ISO 15848-1 actually tests

ISO 15848-1 is a type-test standard for fugitive emissions from industrial valves, and the current edition dates from 2015. It qualifies a valve design by putting it through mechanical and thermal cycles while leakage from the stem seal and body seal is measured. Part 2 of the standard covers acceptance testing on production valves. In short, Part 1 proves that a design can hold, and Part 2 deals with the valves that leave the factory.

The three classifications

A complete rating has three parts: tightness, endurance and temperature.

Tightness class describes how much leaks past the stem seal, measured with helium or methane:

  • Helium: AH ≤ 1.0 × 10⁻⁵ mg/(s·m), BH ≤ 1.0 × 10⁻⁴, CH ≤ 1.0 × 10⁻²
  • Methane: AM ≤ 50 ppmv, BM ≤ 100 ppmv, CM ≤ 500 ppmv

Class A is the tightest. The body seal is checked too, and testing begins with that measurement.

Endurance class is the number of full-stroke cycles the valve completes while staying within its tightness class:

  • Isolating valves: CO1 is 205 cycles, CO2 is 1,500 and CO3 is 2,500
  • Control valves: CC1 is 20,000 cycles, CC2 is 60,000 and CC3 is 100,000

Each step up adds thermal cycles as well, and a valve must pass the lower class before it can claim the next.

Temperature class states the range tested: −196 °C, −46 °C, −29 °C, room temperature, 200 °C or 400 °C. Test pressure follows the valve's pressure–temperature rating.

How to read a designation

Take an illustrative result of AH – CO3 – t(200 °C). That means helium testing, the tightest tightness class, 2,500 mechanical cycles and thermal testing up to 200 °C. Compare it with CH – CO1 at room temperature. Both are “ISO 15848-1” valves, yet they are very different products.

Packed valves also show an SSA figure, the number of stem-seal adjustments needed to stay in class. SSA 0 means none were needed. Ask for it, and ask whether the tested valve actually had a bellows.

Why it matters for bellow seal valves

Tightness classes apply to the stem sealing system, which is exactly where a bellows earns its place. The bellows keeps process fluid away from the sliding stem, so the stem is no longer the usual leak path. Even so, the class a particular design reaches depends on bellows construction, any auxiliary packing and assembly quality. Never assume Class A because a bellows is fitted. Read the report.

What to ask your supplier

  • The complete type-test report, not just a line on the datasheet
  • The edition used, since older certificates may cite the 2006 edition, which counted cycles differently
  • The valve type, sizes and pressure classes the report covers
  • Test gas, tightness class, endurance class and temperature class
  • The test laboratory, and whether the test was witnessed

Related standards

TA Luft, the German air-quality guideline, uses ISO 15848-1 as its test basis while setting its own leakage limits. API 622 and API 624 deal with graphite-packed valves rather than bellows designs. If your project specification names one of these, confirm how it maps to the ISO classes before accepting an alternative.

Fugitive emission performance is something you can verify on paper before a valve reaches your plant. Freture Techno Pvt. Ltd. is a Mumbai-based manufacturer of bellow seal globe valves, gate valves, control globe valves and extended-stem designs. Share your specification and the team can discuss documentation against it. For the wider selection process, read our guide on how to select a bellow seal valve for critical service.

No comments: